1 Year Warranty on Parts and Lifetime Free Service
Features:
| Photometric | |
| Linear Measurement Range | 0.003 to 3.0 Absorbance Units (A) | 
| Photometric Accuracy | ± (1% of the reading + 0.01 A) from 0 to 1.5A ± (2% of the reading + 0.01 A) from 1.5 to 3.0 A | 
| Stability | Drift of no more than 0.005A in 8 hours | 
| Warm up time | 45 seconds, built-inn | 
| Light Source | Tungsten Lamp | 
| Standard Wavelengths | Standard: 405, 450, 492, 630nm Six Filter UV: 405, 450, 492, 630, 545 and 340nm Six Filter VIS: 405, 450, 492, 630, 600 and 545nm | 
| Type of Filter | 3-cavity hard coat interference filter, 10nm half band pass typical | 
| Vessel | Single, double or break apart strips up to 12 wells long 3 strip loading capacity | 
| Electronic and Software | |
| Speed | Reads, calculates and prints results for up to 12 wells in about 30 seconds | 
| Display | LCD, 16” characters, 5x7 dot matrix | 
| Internal Printer | Thermal, dot matrix, 20 characters per line | 
| Keyboard | 16-key, membrane switch, 4x4 | 
| Calculation Modes | Single point calibration, Multi-point calibration with regression or point to point curve fit, cutoff, cutoff control, % Absorbance Multi-Point, Uptake | 
| Serial Port | Output only, 2400 Baud, 1 start bit, 8 data, 1 stop, no parity, no handshake | 
| Power Source | Switch selectable power supply (115V or 230V indicated) Voltage Source 110-120/220-240 VAC from 50 to 60 Hz, CAT II Power consumption is less than 50 watts Fuse: two 1/2A, T rating, 250V, 3AG type fuse All power cords must be approved for the country of use | 
| Certifications and Compliances | NRTL Listed Standard UL -61010A-1, Electrical Equipment for Laboratory Use. CE Certificate of Conformity. Conforms to the following standards: EN 61010-1, EN 61326, following the provisions of the 98/79/EC IVD directive | 
| Physical | |
| Enclosure | ABS Plastic cover with metal base | 
| Dimensions | Approx. 9”x12”x3”, (23x30x8cm) 13 lbs (5.9 Kg) | 
| Environmental Conditions for Safe Operation | Indoor Use Altitude up to 2000m Temperature 5ºC to 40ºC (Although it may be safe to operate in these conditions, t may not be suitable for the performance of your tests; check with your supplier.) Humidity 80% for temperature up to 31ºC, decreasing linearity to 50% humidity at 40ºC Mains supply voltage fluctuations not to exceed ±10% of nominal voltage | 
| Recommended Environmental Conditions | 
 | 
| Recommended Operating Temperature | 18-35ºC | 
| Recommended Operating Humidity | Less than 80% | 
| Optional Accessories | |
| Available from your dealer | DRI-DYE Check Strips for instrument QC, replacement lamps, fuses, thermal paper, serial cable |